Protection relay technology has advanced dramatically over the years offering the end user a complex array of features. Often the relays will however only require a fraction of the settings available to be utilized. Protection relays whether they are electro-mechanical or microprocessor based are precise measuring devices and require periodic testing to prove correct functionality.
Whether power supply, industrial, or power station applications – every operator of medium voltage switchgear has different process-specific requirements. These are High Reliability, Personal Safety, and Low Space Requirements.
Besides the corresponding voltage levels, there are other additional aspects like environmental independence, maintenance-free design, compactness, security of investment, cost-efficiency, service friendliness, and flexibility – always according to the specific demand.
Hi- Tech Engineers medium voltage offering as an alliance partner with Schneider Electric completely designed in-house in consultation with Schneider Electric. Hi-Tech Engineers manufacture 12KV/ 24KV/36KV Circuit Breaker Panel complies with the requirements of standard IEC 62271-200, best-in-class VCB panels are tested with the VCB & SF6 circuit breakers supplied by Schneider Electric.
Hi-Tech Engineers compiles with the main international standards:
- IEC 62271-200 Standard for high A.C. Metal enclosed switchgear and for rated Voltages above 3.3 kV up to and including 36 kV
Medium Voltages switchgear Products:
- Outdoor & Indoor Metal Clad Vacuum Circuit Breaker, Rating: 3.3 to 36 kV 26.3KA,31.5 KA & 40KA ,800 AMP TO 2500A, fully
- compartmentalized of LT Chamber Compartment, CTs & PTs Compartment Breaker Compartment, Cable Compartment On Both Sides LHS & RHS with Aluminum / Copper options are Offering with Powder Coating, as per Schneider Electric
Application
- Indoor & Outdoor - Power & Distributions Transformer Feeder, Motor Feeder Capacitor Feeder
SAFETY
- Door Interlocks are provided such that breaker closing is prevented in intermediate position between service you can’t open the VCB
- Panel door only Test positions only open the VCB Panel Door.
- Breaker can be inserted only when control plug & socket is in position and Control plug & Socket can be removed only in isolated position
- In Easy Pact VCB Mechanical & Electrical Emergency tripping arrangement can be provided outside the cubicle
- If Breakers in isolation position safety shutter close automatically. The operating Mechanism is either manual / motorized spring charged. The clearance between the phase to phase and to earth on the Breakers as well as the bus Busbar are as per the relevant standards. The VCB is very robust and virtually maintenance free
Features
- Compact design, Available in Both Indoor and Outdoor version. Simple Construction, Floor mounting, free standing & simple installation type
- Fully compartmentalized design / separate chambers for breaker, bus bar, cable & CT and PTs with Instruments & Relay compartment
- Fabricated sheet metal parts are pre-treated by eleven tank processes before power coating of customer colour choice
- Extensible on both sides and Aesthetically Superior with Reliability & Continuity of Supply
- Minimum downtime, Safe, Easy to maintain and Transportable & Ready to Install
- Withdrawable truck assembly and Metal enclosed, No direct access to live parts, No fire hazard
- Fully compartmentalized design / separate chambers for breaker, bus bar, cable & CT and PTs with Instruments & Relay compartment
- Fabricated sheet metal parts are pre-treated by eleven tank processes before power coating of customer colour choice
- Extensible on both sides and Aesthetically Superior with Reliability & Continuity of Supply
- Horizontal draw out & horizontal isolation design, high electrical and mechanical life
- Easy interchangeability of breakers of same rating
- Service, Test & Isolated positions inside the cubicle with front door closed
Construction
- Application: Indoor / Outdoor Design
- Compartmentalized: Fully compartmentalized of LT Chamber Compartment, CTs & PTs
- Compartment Breaker Compartment Cable (Outgoing) Termination Compartment
- Future Extension : On Both Sides LHS & RHS
- Bus bar:Aluminum / Copper options
- Bus bar: Aluminum / Copper options
- Powder Coating (as per the requirements)
Navigation
Our Location
- Office Address
S No.86/4/1 Near Dari Bridge,Jambhulwadi Pune-411046,India
- +919011074245 +919822952577
- hitechengineerspune@gmail.com
@ copyright 2022 by Hitech Engineers Pune All Rights Reserved.